This is the genuine OEM ignitor electrode (part number 1179966) for the ICP / Tempstar / Heil RGS243HSFA0AAAA gas/electric package unit. The ignition electrode delivers the spark that lights the burner during the heating cycle and, on many designs, also serves as the flame-sensing rod that proves a stable flame. When the electrode's tip erodes, the ceramic insulator cracks, or the gap drifts out of spec, the unit may fail to light, lock out after several trial-for-ignition attempts, or ignite then immediately shut down on a flame-proving fault. A new OEM electrode restores reliable, on-demand ignition.

Specifications

Spec Value
Part Number 1179966
Type Ignitor / Ignition Electrode
Brand ICP / Tempstar / Heil
Function Spark ignition / flame sensing
Fit OEM Direct Replacement

Compatibility

Built for the ICP-family RGS243HSFA0AAAA and the equivalent Tempstar, Heil, and Comfortmaker package units that share this burner assembly. Confirm the OEM part number and mounting-bracket orientation against your existing electrode before installing.

Installation Guide

  1. Safety First — Shut off the gas, disconnect power, and verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the electrode position, gap, and ignition lead routing.
  4. Remove — Disconnect the high-voltage lead and unfasten the electrode from the burner bracket.
  5. Install — Mount the new electrode, set it to the OEM gap, and reconnect the ignition lead per your photo.
  6. Test — Restore gas and power, then confirm clean ignition and stable flame proving.

Signs You Need a Replacement

  • No spark or weak, intermittent spark at the burner
  • Unit locks out after repeated ignition attempts
  • Cracked or carbon-fouled ceramic insulator
  • Burner lights then drops out on a flame fault

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS243HSFA0AAAA — OEM Part 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS243HSFA0AAAA — OEM Part 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS243HSFA0AAAA — OEM Part 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.