Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Ignitor Electrode for RGS240HDFA0AAAA — Direct Spark Ignition | Ships Today
ICP

ICP Ignitor Electrode for RGS240HDFA0AAAA — Direct Spark Ignition | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM ignitor electrode (part number 1179966 — IGNITOR ELECTRODE) delivers the high-voltage spark that lights the gas burner on your ICP / Tempstar / Heil RGS240HDFA0AAAA rooftop gas-electric package unit. On each heat call, the control board energizes the electrode, producing a spark across the gap to ignite the burner gas. The same electrode assembly typically doubles as part of the flame-proving circuit, confirming the burner has lit. When the electrode cracks, fouls with carbon, or the gap drifts out of spec, the unit fails to ignite — or lights and then locks out on a failed flame signal. Common symptoms include no ignition on a heat call, repeated ignition-lockout codes, delayed or rough light-off, and short cycling on the burner.

Specifications

Spec Value
OEM Part Number 1179966
Type Direct Spark Ignition Electrode
Brand ICP / Tempstar / Heil
Function Burner ignition / flame sensing
Application Gas burner — rooftop package unit
Fits Model RGS240HDFA0AAAA

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil RGS240HDFA0AAAA rooftop gas-electric package unit. Verify part number 1179966 and the electrode bracket geometry against your existing part before ordering.

Installation Guide

  1. Safety First — Shut off the gas supply, disconnect power, and verify zero voltage at the unit.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the electrode position, wire routing, and spark-gap orientation before removal.
  4. Remove — Disconnect the high-voltage ignition lead and ground, then unscrew the electrode from the burner bracket.
  5. Install — Mount the new electrode, set the spark gap per the unit spec, and reconnect the ignition lead.
  6. Test — Restore gas and power, call for heat, and confirm clean spark, ignition, and stable flame.

Signs You Need a Replacement

  • No spark or no ignition on a heat call
  • Repeated ignition-lockout fault codes
  • Cracked ceramic insulator or carbon-fouled tip
  • Burner short-cycles or fails to prove flame

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS240HDFA0AAAA — Direct Spark Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS240HDFA0AAAA — Direct Spark Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS240HDFA0AAAA — Direct Spark Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online