This OEM ignitor electrode (part number 1179966) is the ignition component for the gas heat section of your ICP RGS213LFCA0AAAA packaged unit. On a heat call, the control board energizes the igniter to light the main burners, and the electrode confirms a clean, reliable ignition sequence. A cracked, fouled, or worn igniter electrode is one of the most common causes of furnace no-heat and ignition lockout faults. Typical failure symptoms include the burners failing to light, the unit short-cycling on ignition, repeated lockouts after several ignition attempts, and visible cracks, carbon buildup, or erosion on the electrode tip.

Specifications

Spec Value
Part Number 1179966
Type Ignitor Electrode
Brand ICP (Tempstar / Heil)
Function Gas Burner Ignition
Fitment OEM

Compatibility

Designed as the factory-correct ignition electrode for the ICP / Tempstar / Heil RGS213LFCA0AAAA gas heat section. Confirm the bracket geometry and gas orientation match your existing igniter before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, shut off the gas supply, and verify zero voltage with a multimeter.
  2. Access — Remove the service panel to reach the burner and ignition assembly.
  3. Document — Photograph the igniter wiring and mounting position before removing it.
  4. Remove — Disconnect the igniter lead, remove the mounting screw(s), and withdraw the old electrode without touching the ceramic.
  5. Install — Mount the new igniter by its bracket only, never the element, and reconnect the lead per your photo.
  6. Test — Restore gas and power, then verify a clean ignition and stable burner flame on a heat call.

Signs You Need a Replacement

  • Burners will not light on a heat call
  • Repeated ignition lockout after several failed attempts
  • Visible cracks, carbon, or erosion on the electrode tip
  • Short-cycling or intermittent no-heat during cold weather

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS213LFCA0AAAA — OEM Direct Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS213LFCA0AAAA — OEM Direct Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS213LFCA0AAAA — OEM Direct Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.