Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Ignitor Electrode for RGS213HFEA0AAAA — OEM 1179966 | Ships Today
ICP

ICP Ignitor Electrode for RGS213HFEA0AAAA — OEM 1179966 | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine ICP / Tempstar / Heil ignitor electrode, OEM part number 1179966, for the gas furnace model RGS213HFEA0AAAA. The ignitor electrode is responsible for lighting the burner gas at the start of each heating cycle. A worn, cracked, or contaminated electrode causes ignition failures: the furnace cycles on the inducer and gas valve but never lights, or it lights inconsistently and locks out after several failed attempts. Because the electrode sits in the harsh, high-heat environment of the burner assembly, the ceramic insulator can crack and the electrode tip can erode over years of service, making it a routine wear item on no-heat service calls.

Specifications

Spec Value
Part Number 1179966
Type Ignitor Electrode
Brand ICP / Tempstar / Heil
Application Gas furnace burner ignition
Fits Model RGS213HFEA0AAAA

Compatibility

Designed for the ICP / Tempstar / Heil model RGS213HFEA0AAAA and other furnaces in the same family that use ignitor electrode 1179966. Confirm the OEM part number against your existing electrode before ordering, as ignitor geometry is model-specific.

Installation Guide

  1. Safety First — Shut off gas and disconnect power; verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the electrode position and wiring before removal.
  4. Remove — Disconnect the ignitor lead and unscrew the electrode from the burner assembly. Handle the new ceramic gently and avoid touching the tip with bare hands.
  5. Install — Mount the new electrode at the correct gap and position, then reconnect the lead per your photo.
  6. Test — Restore gas and power and confirm clean, reliable ignition on a heat call.

Signs You Need a Replacement

  • Furnace cycles but burners won't light
  • Repeated ignition lockouts after several attempts
  • Cracked ceramic insulator or eroded electrode tip
  • Carbon buildup or soot on the electrode

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS213HFEA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS213HFEA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS213HFEA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online