Overview

This genuine OEM ignitor electrode (part 1179966) is the ignition component for ICP, Heil, and Tempstar gas furnaces. The electrode generates the high-voltage spark that lights the burner gas on a call for heat, and on many systems the same or a paired electrode also senses flame to confirm a successful light. When the electrode tip erodes, cracks its ceramic insulator, or builds up oxide and soot, you'll see failed or delayed ignition, repeated ignition lockouts after several tries, short cycling on flame loss, or no heat at all even though the gas valve is opening. A fresh electrode with the correct gap restores fast, dependable lights.

Specifications

Spec Value
OEM Part Number 1179966
Type Spark / Direct-Spark Ignition Electrode
Function Burner ignition (and flame sensing on paired designs)
Brand ICP / Heil / Tempstar
Application Gas furnace

Compatibility

Factory ignition electrode for ICP, Heil, Comfortmaker, and Tempstar gas furnaces including the RGS213HFAA0AAAA. Confirm the bracket shape and electrode gap match your existing part before installation.

Installation Guide

  1. Safety First — Shut off the gas supply, disconnect electrical power, and verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the electrode position, wire, and gap before removal.
  4. Remove — Disconnect the ignition wire and unscrew the electrode bracket from the burner assembly.
  5. Install — Mount the new electrode, set it to the specified spark gap, and reconnect the ignition lead; do not touch the ceramic with bare oily fingers.
  6. Test — Restore gas and power, then run a heat cycle to confirm a fast, reliable light.

Signs You Need a Replacement

  • Furnace fails to ignite or ignites only after several tries.
  • Repeated ignition lockouts on a heat call.
  • Cracked ceramic insulator or eroded electrode tip.
  • Short cycling caused by lost or weak flame signal.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS213HFAA0AAAA — Direct Spark Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS213HFAA0AAAA — Direct Spark Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS213HFAA0AAAA — Direct Spark Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online