Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Ignitor Electrode for RGS213HDAA0AAAA — OEM Direct Spark Igniter | Ships Today
ICP

ICP Ignitor Electrode for RGS213HDAA0AAAA — OEM Direct Spark Igniter | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM ignitor electrode, ICP part number 1179966, for your ICP, Heil, or Tempstar RGS213HDAA0AAAA gas furnace. The ignitor electrode is positioned at the burner and provides the spark that lights the gas at the start of each heating cycle; on many systems the same or a companion electrode also serves as the flame-sensing rod that confirms a flame is present. When the electrode is cracked, fouled with oxide, or out of position, the furnace fails to light, locks out after several trial-for-ignition attempts, or short-cycles on flame failure — leaving the home without heat. A clean, correctly gapped electrode is essential for fast, reliable ignition.

Specifications

Spec Value
Part Number 1179966
Type Ignitor Electrode (Spark / Direct Ignition)
Brand ICP / Heil / Tempstar
Application Gas Furnace Burner Ignition
Fit OEM Direct Replacement

Compatibility

Direct OEM replacement for the ICP/Heil/Tempstar/Comfortmaker RGS213HDAA0AAAA gas furnace and related ICP-family units that specify the 1179966 ignitor electrode. Confirm against your unit's parts breakdown before ordering.

Installation Guide

  1. Safety First — Shut off the gas supply, disconnect power at the switch and breaker, and verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment door to expose the burner assembly and electrode.
  3. Document — Photograph the electrode position, gap, and ignition lead routing before removal.
  4. Remove — Disconnect the high-voltage lead and unscrew the electrode bracket from the burner.
  5. Install — Mount the new electrode at the factory gap and orientation, then reconnect the ignition lead.
  6. Test — Restore gas and power, call for heat, and confirm a clean spark, light-off, and steady flame sense.

Signs You Need a Replacement

  • Furnace clicks but won't light, or locks out on ignition failure
  • Cracked ceramic insulator or visible carbon buildup
  • Weak, erratic, or no visible spark
  • Short-cycling on flame-sense fault

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS213HDAA0AAAA — OEM Direct Spark Igniter | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS213HDAA0AAAA — OEM Direct Spark Igniter | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS213HDAA0AAAA — OEM Direct Spark Igniter | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online