Overview

This genuine OEM ignitor electrode (part 1179966) provides ignition for the ICP/Tempstar/Heil RGS210SSAA0AAAA gas furnace. On each heat call the control board energizes the ignitor, which heats or sparks at the burner to light the gas as the valve opens. A worn or cracked ignitor electrode is one of the most common reasons a furnace will not light: the unit calls for heat, the inducer runs, the gas valve opens, but no flame is established, and the board locks out after several failed trials. Because the electrode is subjected to repeated thermal cycling, hairline cracks, erosion, and contamination develop over time. Handle the new electrode by its base only — oils from bare fingers can shorten its life.

Specifications

Spec Value
OEM Part Number 1179966
Type Ignitor Electrode
Brand ICP / Tempstar / Heil
Application Gas Furnace Ignition
Mount Burner Assembly

Compatibility

Designed for the ICP/Tempstar/Heil RGS210SSAA0AAAA furnace and other RGS-series units that specify the 1179966 ignitor electrode. Match the part number and mounting bracket to your existing ignitor before ordering.

Installation Guide

  1. Safety First — Disconnect power and shut off the gas, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment door.
  3. Document — Photograph the ignitor wiring, bracket, and burner alignment.
  4. Remove — Disconnect the ignitor lead and unscrew the old electrode from the burner assembly. Handle the new part by its ceramic base only.
  5. Install — Mount the new electrode in the same position and reconnect the lead.
  6. Test — Restore gas and power and confirm a clean light-off on the next heat call.

Signs You Need a Replacement

  • Furnace calls for heat but never lights
  • Visible cracks, erosion, or carbon on the ignitor
  • Control board locks out after repeated ignition trials
  • Delayed or rough ignition with a hard puff at light-off

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS210SSAA0AAAA — OEM Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS210SSAA0AAAA — OEM Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS210SSAA0AAAA — OEM Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online