Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Ignitor Electrode for RGS210SDEA0AAAA — Direct Ignition (1179966) | Ships Today
ICP

ICP Ignitor Electrode for RGS210SDEA0AAAA — Direct Ignition (1179966) | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM ignitor electrode (part #1179966) is the spark/sensing electrode for ICP, Heil, and Tempstar gas furnaces. It delivers the high-voltage spark that lights the burner on a call for heat and, on many designs, also provides flame rectification so the control board can confirm a flame is present. A cracked ceramic insulator, a corroded or eroded electrode tip, or a misaligned gap leads to ignition lockout, delayed ignition, or short cycling on flame failure. Replacing a worn electrode restores reliable, on-demand ignition.

Specifications

Spec Value
Part Number 1179966
Type Ignitor / Sensing Electrode
Ignition Spark / Direct Ignition
Brand ICP / Heil / Tempstar
Application Gas furnace burner

Compatibility

Direct OEM replacement for ICP/Heil/Tempstar model RGS210SDEA0AAAA and related furnaces using this spark ignition electrode. Match the part number and bracket orientation to your existing electrode before installing.

Installation Guide

  1. Safety First — Disconnect power and shut off the gas supply; verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment door.
  3. Document — Photograph the electrode position, gap, and wire routing before removal.
  4. Remove — Disconnect the ignition lead and unscrew the electrode bracket from the burner assembly.
  5. Install — Mount the new electrode, confirm the spark gap, and reconnect the high-voltage lead.
  6. Test — Restore gas and power, then verify clean spark and burner ignition on a heat call.

Signs You Need a Replacement

  • Furnace locks out with no ignition
  • Delayed ignition or rough light-off
  • Cracked ceramic insulator or corroded tip
  • Short cycling on flame-sense failure

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS210SDEA0AAAA — Direct Ignition (1179966) | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS210SDEA0AAAA — Direct Ignition (1179966) | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS210SDEA0AAAA — Direct Ignition (1179966) | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online