This OEM ignitor electrode (part 1179966) provides the spark that lights the burners on ICP/Heil/Tempstar RGS-series gas furnaces. On a heat call, the control board sends high voltage to the electrode tip, creating a spark across the gap to ignite the gas at the burner. The electrode also helps establish a reliable ignition sequence. A cracked ceramic insulator, eroded electrode tip, or incorrect gap leads to failed ignition, delayed ignition with a 'puff,' or lockout after repeated trial-for-ignition attempts.

Specifications

Spec Value
Part Number 1179966
Type Ignitor Electrode (Direct Spark)
Brand ICP / Heil / Tempstar
Application Gas Furnace Burner Ignition
Material Ceramic insulator with metal electrode

Compatibility

Direct OEM replacement for the ICP/Tempstar/Heil RGS210SDCA0AAAA furnace and related RGS-series gas models using the 1179966 electrode. Match the bracket and electrode geometry to your existing part before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect power, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment door.
  3. Document — Photograph the electrode position, gap, and wiring before removal.
  4. Remove — Disconnect the ignition lead and unscrew the electrode from the burner assembly.
  5. Install — Mount the new electrode, confirm the spark gap matches spec, and reconnect the lead.
  6. Test — Restore gas and power, then watch a full ignition cycle for a clean, prompt light-off.

Signs You Need a Replacement

  • Furnace fails to ignite or locks out
  • Delayed ignition with a 'whoomp' or puff
  • Cracked ceramic insulator or eroded electrode tip
  • Repeated trial-for-ignition cycling

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS210SDCA0AAAA — OEM Direct Spark | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS210SDCA0AAAA — OEM Direct Spark | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS210SDCA0AAAA — OEM Direct Spark | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online