Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Ignitor Electrode for RGS210SDAA0AAAA — OEM Spark Igniter | Ships Today
ICP

ICP Ignitor Electrode for RGS210SDAA0AAAA — OEM Spark Igniter | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM ignitor electrode (part number 1179966) for the ICP / Tempstar / Heil RGS210SDAA0AAAA gas furnace. The electrode delivers the high-voltage spark that lights the burner gas on each call for heat, and on many systems it also serves as the flame-sensing surface that confirms ignition. A cracked porcelain insulator, eroded electrode tip, or carbon buildup weakens the spark and prevents reliable lightoff, leading to ignition lockouts and no-heat calls. Installing a fresh OEM electrode with the correct gap restores strong, consistent ignition and dependable flame proving.

Specifications

Spec Value
Part Number 1179966
Type Spark Ignitor Electrode
Brand ICP / Tempstar / Heil
Application Gas Furnace Burner Ignition
Fitment OEM Replacement

Compatibility

Direct-fit for the ICP RGS210SDAA0AAAA gas furnace and shared across RGS-series furnaces sold under ICP, Tempstar, Heil, Comfortmaker and Arcoaire brands using this spark-ignition electrode. Match the part number on your existing electrode before ordering.

Installation Guide

  1. Safety First — Disconnect power and shut off the gas supply, then verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the electrode bracket position and ignition lead routing before removing.
  4. Remove — Disconnect the high-voltage ignition lead and unfasten the electrode bracket from the burner assembly.
  5. Install — Mount the new electrode, confirm the correct spark gap, and reconnect the ignition lead per your photo.
  6. Test — Restore gas and power, then verify a clean spark, prompt lightoff, and stable flame.

Signs You Need a Replacement

  • Furnace clicks but won't ignite; ignition lockout
  • Cracked or chipped porcelain insulator
  • Weak, intermittent, or no spark at the electrode
  • Burner lights then drops out on flame-sense failure

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS210SDAA0AAAA — OEM Spark Igniter | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS210SDAA0AAAA — OEM Spark Igniter | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS210SDAA0AAAA — OEM Spark Igniter | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.