Overview

This OEM ignitor electrode (part 1179966) is the ignition component for the ICP/Tempstar/Heil RGS210LTEA0AAAA gas furnace. The electrode delivers the high-voltage spark that ignites the gas at the burner during each heat call. A precise spark gap and a clean, undamaged electrode tip are essential for fast, reliable light-off and consistent flame establishment.

Over time the electrode tip erodes, cracks, or accumulates carbon and corrosion, which weakens or eliminates the spark. The most common symptom of a failing ignitor electrode is a furnace that clicks or attempts ignition but won't light, locks out after several failed trials, or produces delayed ignition with a noticeable "whoomph" at start-up. Because it is a wear item directly in the flame path, the electrode is a frequent no-heat culprit.

Specifications

Spec Value
OEM Part Number 1179966
Type Ignitor Electrode (Direct Spark Ignition)
Function High-voltage burner spark / light-off
Brand ICP / Tempstar / Heil / Comfortmaker
Fits Model RGS210LTEA0AAAA
Fitment OEM Direct Replacement

Compatibility

This electrode is the OEM-specified ignition part for the ICP-family RGS210LTEA0AAAA gas furnace and the related Tempstar, Heil, Comfortmaker, and Arcoaire RGS210 units that use part 1179966. Confirm your furnace's ignition part number before ordering, and inspect the ceramic insulator and bracket for a match.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker and shut off the gas. Verify zero voltage before working near the burner assembly.
  2. Access — Remove the burner compartment door to reach the ignition assembly.
  3. Document — Photograph the electrode position, wire routing, and spark-gap location relative to the burner.
  4. Remove — Disconnect the high-voltage ignition lead, remove the mounting screw(s), and withdraw the old electrode without disturbing the burner.
  5. Install — Mount the new electrode, restore the factory spark gap per the photo, and reconnect the ignition lead securely.
  6. Test — Restore gas and power, initiate a heat call, and confirm a strong spark with prompt, quiet burner ignition and stable flame.

Signs You Need a Replacement

  • Furnace sparks or clicks but the burner won't light
  • Control locks out after repeated failed ignition trials
  • Delayed ignition with a rollout or "whoomph" at start-up
  • Cracked ceramic insulator, eroded tip, or carbon/corrosion buildup

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS210LTEA0AAAA — Direct Spark | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS210LTEA0AAAA — Direct Spark | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS210LTEA0AAAA — Direct Spark | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online