Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Ignitor Electrode for RGS210HREA0AAAA — Direct Ignition Electrode | Ships Today
ICP

ICP Ignitor Electrode for RGS210HREA0AAAA — Direct Ignition Electrode | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM ignitor electrode (part 1179966) provides the ignition spark for the ICP / Heil / Tempstar RGS210HREA0AAAA gas furnace. Mounted at the burner, the electrode delivers the high-voltage spark that lights the gas during each heating cycle, and on many ignition systems the same electrode also serves as the flame-sensing rod that proves the burner has lit. A cracked ceramic insulator, eroded electrode tip, or carbon-fouled probe will cause weak or no spark, repeated ignition lockouts, or a furnace that lights briefly then shuts down on a failed flame-proving signal. Replacing the electrode restores a strong, reliable ignition spark and dependable flame detection.

Specifications

Spec Value
Part Number 1179966
Type Ignition electrode
Brand ICP / Heil / Tempstar
Function Spark ignition / flame sensing
Mounting Burner-mounted electrode
Fit OEM replacement

Compatibility

Designed for the ICP RGS210HREA0AAAA furnace and the related Heil, Tempstar, Day & Night, KeepRite, Comfortmaker, and Arcoaire units that use ignition electrode 1179966. Confirm the electrode bracket and probe layout match your burner before ordering.

Installation Guide

  1. Safety First — Disconnect power and shut off the gas, then verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the electrode position, gap, and wire routing before disconnecting.
  4. Remove — Disconnect the high-voltage lead and unscrew the electrode from the burner assembly.
  5. Install — Mount the new electrode, set the correct spark gap, and reconnect the ignition lead per your photo.
  6. Test — Restore gas and power, then confirm a strong spark and stable flame on a call for heat.

Signs You Need a Replacement

  • No spark or a weak, intermittent spark at the burner.
  • Repeated ignition lockouts after several failed attempts.
  • Burner lights briefly then shuts down (flame not proven).
  • Cracked ceramic insulator or visibly eroded/fouled electrode tip.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS210HREA0AAAA — Direct Ignition Electrode | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS210HREA0AAAA — Direct Ignition Electrode | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS210HREA0AAAA — Direct Ignition Electrode | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR