Overview

This OEM ignitor electrode (part number 1179966) provides the ignition source for the burners on the ICP/Heil/Tempstar RGS210HFEA0AAAA gas furnace. On each heat call the control board energizes the ignitor to light the gas at the burner, and the same or a paired electrode confirms flame. A cracked ceramic, eroded tip, or open electrode prevents the furnace from lighting — the inducer and gas valve may cycle but no flame is established, often locking the board out after several failed attempts. Replacing it with the genuine OEM electrode restores fast, dependable ignition and proper flame confirmation.

Specifications

Spec Value
Part Number 1179966
Type Ignitor Electrode
Brand ICP / Heil / Tempstar
Application Gas Furnace Burner Ignition
Fit OEM Replacement

Compatibility

Designed for the ICP/Heil/Tempstar RGS210HFEA0AAAA and other RGS-family gas furnaces that use OEM ignitor electrode 1179966. Confirm the part number and bracket orientation against your existing electrode before ordering, as ignitor geometry is model-specific.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, shut off the gas, and verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the electrode position, gap, and wire routing before removal.
  4. Remove — Disconnect the ignition lead and unscrew the electrode from the burner assembly. Handle the ceramic carefully and avoid touching the new tip.
  5. Install — Mount the new electrode at the original gap and orientation, then reconnect the ignition lead.
  6. Test — Restore gas and power and confirm the burners light promptly and flame is sensed on the first ignition attempt.

Signs You Need a Replacement

  • Furnace cycles the inducer and gas valve but never lights.
  • Control board locks out after repeated failed ignition attempts.
  • Cracked ceramic insulator or eroded/burned electrode tip.
  • Intermittent ignition or delayed, rough light-off.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS210HFEA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS210HFEA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS210HFEA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.