Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Ignition Electrode for RGS303SSFA0AAAA — OEM Igniter | Ships Today
ICP

ICP Ignition Electrode for RGS303SSFA0AAAA — OEM Igniter | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM ignitor electrode (part number 1179966) for the ICP / Tempstar / Heil RGS303SSFA0AAAA gas furnace. The ignition electrode delivers the spark or ionization point that lights the burner on a call for heat, and on many designs also helps confirm flame presence to the control board. A cracked ceramic insulator, eroded electrode tip, or incorrect gap leads to failed ignition, repeated lockouts, or short cycling on the safety circuit. Installing a fresh OEM electrode restores reliable, on-demand ignition and proper flame-sensing feedback.

Specifications

Spec Value
Part Number 1179966
Description Ignitor / Ignition Electrode
Type Ignition Electrode
Brand ICP / Tempstar / Heil
Application Gas Furnace Burner Ignition
Fitment OEM

Compatibility

Designed for the ICP-built RGS303SSFA0AAAA furnace and equivalent Tempstar, Heil, and Comfortmaker models. Match the bracket shape, electrode length, and connector to your existing part before installing.

Installation Guide

  1. Safety First — Disconnect electrical power and shut off the gas supply, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment/service panel.
  3. Document — Photograph the electrode position, bracket, and wire routing before removal.
  4. Remove — Disconnect the ignition lead, remove the mounting screw(s), and lift out the old electrode.
  5. Install — Mount the new electrode, set the spark gap per spec, and reconnect the ignition lead per your photo.
  6. Test — Restore gas and power, then watch a full ignition cycle to confirm reliable light-off and steady flame.

Signs You Need a Replacement

  • Furnace clicks or sparks but will not light the burner.
  • Repeated ignition lockouts or short cycling on the safety.
  • Cracked ceramic insulator or visibly eroded electrode tip.
  • Weak, intermittent, or no spark at the burner.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS303SSFA0AAAA — OEM Igniter | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS303SSFA0AAAA — OEM Igniter | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS303SSFA0AAAA — OEM Igniter | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online