Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter for RGS303HDAA0AAAA — Direct Spark Electrode | Ships Today
ICP

ICP Igniter for RGS303HDAA0AAAA — Direct Spark Electrode | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM ignitor electrode (part 1179966) is the original-equipment ignition component for the ICP/Tempstar/Heil RGS303HDAA0AAAA gas furnace. The electrode delivers the high-voltage spark that lights the burner gas at the start of each heat cycle and, on many designs, also serves as the flame-sensing element confirming a successful light. Over time the electrode tip erodes, the ceramic insulator cracks, and the spark gap drifts out of spec — leaving the furnace unable to ignite or unable to prove flame. Common failure symptoms include the furnace clicking/sparking but not lighting, ignition lockout after several failed tries, short-cycling on flame loss, or a cold home with no heat output. Replacing with the correct OEM electrode restores a strong, correctly gapped spark and reliable ignition every cycle.

Specifications

Spec Value
Part Number 1179966
Type Direct Spark Ignitor Electrode
Brand ICP / Tempstar / Heil
Function Ignition / Flame Sense Electrode
Application Gas Furnace Burner
Fitment OEM Replacement

Compatibility

Direct OEM replacement for the ICP/Tempstar/Heil RGS303HDAA0AAAA furnace and related models in the same family that use ignitor electrode 1179966. Confirm the part number and electrode bracket style against the original before installing.

Installation Guide

  1. Safety First — Disconnect electrical power and shut off the gas supply, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the electrode position, spark gap, and wire routing before removing.
  4. Remove — Disconnect the ignition lead and unscrew the electrode bracket from the burner assembly.
  5. Install — Mount the new OEM electrode, set the correct spark gap, and reconnect the ignition lead per your photo.
  6. Test — Restore gas and power, start a heat cycle, and confirm the burner lights promptly and proves flame.

Signs You Need a Replacement

  • Furnace sparks or clicks but the burner never lights
  • Repeated ignition attempts ending in lockout
  • Burner lights then drops out on flame-sense failure
  • Cracked ceramic insulator or visibly eroded electrode tip

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS303HDAA0AAAA — Direct Spark Electrode | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS303HDAA0AAAA — Direct Spark Electrode | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS303HDAA0AAAA — Direct Spark Electrode | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online