Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter for RGS240HSAA0AAAA - OEM Ignitor Electrode | Ships Today
ICP

ICP Igniter for RGS240HSAA0AAAA - OEM Ignitor Electrode | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM ignitor electrode (part 1179966) lights the burners on the ICP / Tempstar / Heil RGS240HSAA0AAAA rooftop gas-electric package unit. The electrode delivers the high-voltage spark that ignites gas at the burner on each heating call and, on many of these assemblies, also serves the flame-sensing function that proves the burner has lit. A cracked ceramic insulator, eroded electrode tip, or wrong gap is a leading cause of no-heat lockouts and short-cycling on ignition fault. Installing the genuine OEM electrode restores the correct spark gap, rod position, and insulator rating so the ignition control proves flame reliably instead of locking out.

Specifications

Spec Value
Part Number 1179966
Type Ignitor Electrode (Spark / Direct Ignition)
Brand ICP / Tempstar / Heil
Function Burner ignition / flame sensing
Fit OEM Direct Replacement

Compatibility

Made for the ICP-family RGS240HSAA0AAAA packaged rooftop unit and shared with the matching Tempstar, Heil, and Comfortmaker RGS240 builds. Verify the part number on your existing electrode and the burner bracket style before ordering.

Installation Guide

  1. Safety First - Disconnect power and close the manual gas valve, then verify zero voltage with a multimeter.
  2. Access - Remove the burner-compartment service panel.
  3. Document - Photograph the electrode position, gap, and wire routing before removing.
  4. Remove - Disconnect the high-voltage lead, unscrew the electrode bracket, and lift the old electrode out.
  5. Install - Mount the new electrode at the factory gap and reconnect the ignition lead per your photo.
  6. Test - Restore gas and power and confirm the burner sparks, lights, and proves flame without lockout.

Signs You Need a Replacement

  • No heat with the unit locking out on ignition fault.
  • Weak, intermittent, or missing spark at the burner.
  • Cracked or chipped ceramic insulator.
  • Burner that lights then drops out on failed flame sense.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS240HSAA0AAAA - OEM Ignitor Electrode | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS240HSAA0AAAA - OEM Ignitor Electrode | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS240HSAA0AAAA - OEM Ignitor Electrode | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online