Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter Electrode for RGS303SFEA0AAAA — OEM 1179966 Ignition | Ships Today
ICP

ICP Igniter Electrode for RGS303SFEA0AAAA — OEM 1179966 Ignition | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM igniter electrode, part number 1179966, for the ICP / Tempstar / Heil RGS303SFEA0AAAA gas furnace. The igniter electrode delivers the spark (or surface ignition source) at the burner that lights the gas at the start of every heat cycle. Because it is exposed to direct flame and thermal cycling, the electrode is a wear item — the tip erodes, cracks, or carbons over, and ignition becomes weak or intermittent. A worn electrode is one of the most common causes of a furnace that clicks but fails to light, locks out, or short-cycles on ignition failure. Installing a fresh OEM electrode restores reliable first-try ignition.

Specifications

Spec Value
OEM Part Number 1179966
Type Igniter Electrode
Brand ICP / Tempstar / Heil
Application Gas Furnace Burner Ignition
Fitment OEM Direct Replacement

Compatibility

Factory-specified ignition electrode for the ICP Tempstar Heil RGS303SFEA0AAAA and shared across related ICP-family gas furnaces. Confirm your unit uses part number 1179966 before ordering and match the mounting bracket orientation of the original.

Installation Guide

  1. Safety First — Shut off gas at the valve, disconnect power at the switch and breaker, and verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the electrode position, gap, and ignition lead routing before removal.
  4. Remove — Disconnect the ignition lead and unfasten the electrode bracket from the burner assembly.
  5. Install — Mount the new electrode at the factory position and gap, then reconnect the ignition lead per your photo. Handle the ceramic insulator by the bracket only.
  6. Test — Restore gas and power, then run a heat cycle to confirm a strong, immediate ignition.

Signs You Need a Replacement

  • Furnace clicks or sparks but fails to light.
  • Repeated ignition lockouts or short-cycling on startup.
  • Cracked ceramic insulator or eroded/carboned electrode tip.
  • Delayed ignition with a noticeable "whoomp" at light-off.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS303SFEA0AAAA — OEM 1179966 Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS303SFEA0AAAA — OEM 1179966 Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS303SFEA0AAAA — OEM 1179966 Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online