Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter Electrode for RGS303SDFA0AAAA — OEM 1179966 | Ships Today
ICP

ICP Igniter Electrode for RGS303SDFA0AAAA — OEM 1179966 | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM igniter electrode, ICP part number 1179966, for the ICP / Tempstar / Heil RGS303SDFA0AAAA gas furnace. The electrode delivers the high-voltage spark that ignites the gas at the burner during the ignition sequence; on many ICP designs the same electrode assembly also senses flame to confirm a successful light. A cracked ceramic insulator, eroded tip, or carbon-fouled electrode prevents reliable ignition — the furnace will lock out after several failed trials, short-cycle, or fail to produce heat at all. Replacing a worn electrode restores fast, consistent light-off.

Specifications

Spec Value
Part Number 1179966
Type Igniter Electrode
Brand ICP / Tempstar / Heil
Insulator Ceramic
Application Gas furnace burner ignition
Fitment OEM Replacement

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil RGS303SDFA0AAAA gas furnace and related ICP-family units that use the 1179966 igniter electrode. Confirm the part number on your existing electrode before ordering.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, shut off the gas, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner/service panel to reach the burner assembly.
  3. Document — Photograph the electrode position, gap, and lead routing before removal.
  4. Remove — Disconnect the ignition lead and unscrew the old electrode from the burner bracket. Handle the ceramic gently.
  5. Install — Mount the new electrode, set it per the OEM gap, and reconnect the lead per your photo.
  6. Test — Restore gas and power, then watch a full ignition cycle to confirm a clean, immediate light.

Signs You Need a Replacement

  • Furnace locks out after repeated failed ignition trials.
  • Weak, intermittent, or absent spark.
  • Cracked ceramic insulator or eroded/carbon-fouled tip.
  • Short-cycling or no heat despite gas and power present.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS303SDFA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS303SDFA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS303SDFA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online