Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter Electrode for RGS303LTAA0AAAA — Direct Spark | Ships Today
ICP

ICP Igniter Electrode for RGS303LTAA0AAAA — Direct Spark | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM igniter electrode (part number 1179966) is the ignition component for the ICP/Heil/Tempstar RGS303LTAA0AAAA gas furnace. The electrode generates the spark that lights the burner gas on each heat call and, on combined sense/ignite designs, monitors the resulting flame so the control board knows ignition succeeded. Because it sits directly in the burner flame path, the electrode tip erodes, cracks, or builds up oxide over time. A failing electrode shows up as a furnace that clicks or sparks but won't light, ignites then immediately shuts down on a flame-sense fault, or short-cycles on the burner. Replacing this electrode with the correct OEM part restores fast, reliable light-off and stable burner operation through the heating season.

Specifications

Spec Value
OEM Part Number 1179966
Type Igniter / Spark Electrode
Brand ICP / Heil / Tempstar
Function Direct Spark Ignition
Application Gas Furnace Burner
Fits Model RGS303LTAA0AAAA

Compatibility

Built for the ICP/Heil/Tempstar/Comfortmaker RGS303LTAA0AAAA gas furnace and other ICP-family models specifying electrode part 1179966. Verify the electrode bracket, gap, and rod geometry match the unit you are servicing before installing.

Installation Guide

  1. Safety First — Shut off the gas supply and disconnect electrical power, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner/service panel to expose the burner assembly.
  3. Document — Photograph the electrode position, ignition wire routing, and ground strap before disconnecting.
  4. Remove — Disconnect the high-voltage ignition lead and remove the mounting screw(s) holding the old electrode.
  5. Install — Mount the new electrode, set it in the burner flame path, and reconnect the ignition lead per your photo.
  6. Test — Restore gas and power, run a heat call, and confirm prompt spark, light-off, and a steady flame.

Signs You Need a Replacement

  • Furnace sparks or clicks but the burner won't ignite.
  • Burner lights then drops out on a flame-sense / ignition lockout.
  • Cracked ceramic insulator or eroded electrode tip.
  • Repeated ignition retries and short-cycling on heat calls.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS303LTAA0AAAA — Direct Spark | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS303LTAA0AAAA — Direct Spark | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS303LTAA0AAAA — Direct Spark | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online