Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter Electrode for RGS300SEFA0AAAA — Direct Spark | Ships Today
ICP

ICP Igniter Electrode for RGS300SEFA0AAAA — Direct Spark | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM igniter electrode, ICP part number 1179966, for the ICP, Tempstar, and Heil RGS300SEFA0AAAA gas furnace. The electrode produces the high-voltage spark that lights the burner on a call for heat and, in many designs, also serves to sense the resulting flame. A cracked ceramic insulator, eroded electrode tip, or incorrect spark gap will cause failed ignition, repeated retries, or flame-sense lockouts.

Replacing a worn electrode restores reliable first-try ignition and prevents the comfort and safety lockouts that come from a weak or missing spark.

Specifications

Spec Value
Part Number 1179966
Type Spark igniter electrode
Brand ICP / Tempstar / Heil
Function Burner ignition / flame sensing
Fit OEM replacement

Compatibility

Built for the ICP / Tempstar / Heil RGS300SEFA0AAAA and related RGS-series gas furnaces specifying OEM part 1179966. Verify the electrode shape and mounting against your existing part before ordering.

Installation Guide

  1. Safety First — Disconnect power and shut off the gas supply; verify zero voltage with a multimeter.
  2. Access — Remove the burner/service panel to reach the ignition assembly.
  3. Document — Photograph the electrode position, wire routing, and spark gap before removal.
  4. Remove — Disconnect the ignition lead and unscrew the electrode bracket from the burner.
  5. Install — Mount the new electrode, set the spark gap to OEM spec, and reconnect the lead per your photo.
  6. Test — Restore gas and power, call for heat, and confirm a strong spark and stable flame.

Signs You Need a Replacement

  • Furnace clicks but burner fails to light
  • Repeated ignition retries or hard lockout
  • Cracked or carbon-fouled ceramic insulator
  • Weak, erratic, or missing spark at the electrode tip

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS300SEFA0AAAA — Direct Spark | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS300SEFA0AAAA — Direct Spark | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS300SEFA0AAAA — Direct Spark | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online