Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter Electrode for RGS300SDFA0AAAA — Direct Spark | Ships Today
ICP

ICP Igniter Electrode for RGS300SDFA0AAAA — Direct Spark | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM igniter electrode (part #1179966) for the ICP/Tempstar/Heil RGS300SDFA0AAAA furnace is the spark ignition electrode that lights the burner on a call for heat. The electrode generates a high-voltage spark across a precise gap to ignite the gas at the burner, and in many assemblies it also serves the flame-sensing function. Over time the electrode tip erodes, the ceramic insulator cracks, or carbon and corrosion build up, all of which weaken or eliminate the spark. Typical symptoms are a furnace that clicks but won't light, repeated ignition lockouts, delayed ignition with a noticeable gas smell, or short-cycling on a failed flame signal.

Specifications

Spec Value
Part Number 1179966
Type Spark Ignition Electrode
Brand ICP / Tempstar / Heil
Function Direct-Spark Ignition
Fit OEM

Compatibility

Designed for the ICP RGS300SDFA0AAAA and the Tempstar, Heil, Comfortmaker, and other International Comfort Products furnaces using this ignition electrode. Match part number 1179966 to your existing electrode before ordering.

Installation Guide

  1. Safety First — Shut off the gas supply, disconnect power, and verify zero voltage with a multimeter.
  2. Access — Remove the furnace service panel to reach the burner assembly.
  3. Document — Photograph the electrode position, gap, and wiring before removal.
  4. Remove — Disconnect the ignition lead and unfasten the old electrode from the burner bracket, handling the ceramic carefully.
  5. Install — Mount the new electrode at the correct gap and orientation, then reconnect the lead per your photo.
  6. Test — Restore gas and power, call for heat, and confirm a strong spark and clean burner ignition.

Signs You Need a Replacement

  • Furnace clicks but the burner won't light
  • Repeated ignition lockouts or no spark
  • Cracked ceramic insulator or eroded electrode tip
  • Delayed ignition or short-cycling on flame loss

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS300SDFA0AAAA — Direct Spark | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS300SDFA0AAAA — Direct Spark | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS300SDFA0AAAA — Direct Spark | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online