This OEM igniter electrode (part 1179966) is responsible for lighting the burners in your ICP RGS300HEFA0AAAA gas furnace. The electrode delivers the spark that ignites the gas at the burner, starting every heat cycle. A cracked ceramic insulator, eroded electrode tip, or carbon-fouled gap is the usual cause of failure. Common symptoms include no ignition, repeated failed light-off attempts, the furnace locking out after several tries, or short-cycling on a call for heat. Because it is a wear item exposed to high heat on every cycle, the igniter electrode is one of the most replaced components in a gas furnace.

Specifications

Spec Value
Part Number 1179966
Type Igniter Electrode
Brand ICP (Tempstar / Heil)
Function Burner Ignition
Fit OEM Direct Replacement

Compatibility

Direct OEM fit for the ICP / Tempstar / Heil RGS300HEFA0AAAA gas furnace. Confirm the OEM part number against your unit's parts list to ensure the electrode geometry and mounting match your burner assembly.

Installation Guide

  1. Safety First — Shut off the gas supply and disconnect power, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position, wiring, and gap before removing anything.
  4. Remove — Disconnect the igniter lead and unscrew the electrode from the burner bracket. Handle by the base only — never touch the element.
  5. Install — Mount the new electrode at the correct position and reconnect the ignition lead per your photo.
  6. Test — Restore gas and power, then confirm clean ignition on the first call for heat.

Signs You Need a Replacement

  • Furnace fails to ignite or makes repeated failed attempts.
  • Visible crack in the ceramic insulator or eroded electrode tip.
  • Control board lockout after multiple ignition tries.
  • Intermittent ignition or short-cycling on heat calls.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS300HEFA0AAAA — Direct-Spark Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS300HEFA0AAAA — Direct-Spark Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS300HEFA0AAAA — Direct-Spark Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online