The 1179966 igniter electrode is the OEM ignition component for the ICP Tempstar Heil RGS244HEEA0AAAA gas furnace. On a call for heat, the control board energizes the igniter, which heats to glowing temperature and lights the burner gas. Because it cycles through extreme heating and cooling on every call, the igniter is a common wear item — the brittle element eventually cracks or burns open. When it fails, the furnace runs its inducer and gas valve sequence but never lights, then locks out. Installing the correct OEM igniter restores fast, reliable ignition.

Specifications

Spec Value
Part Number 1179966 (IGNITOR ELECTRODE)
Type Hot Surface Igniter Electrode
Brand ICP / Tempstar / Heil
Voltage 120V (typical)
Application Gas Furnace Ignition
Fitment OEM Replacement

Compatibility

Designed as the factory replacement igniter electrode for the ICP Tempstar Heil RGS244HEEA0AAAA and related furnaces that use the 1179966 igniter. Match the connector and mounting bracket to your existing part before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment door to reach the igniter.
  3. Document — Photograph the igniter position and wiring before removal.
  4. Remove — Unplug the connector, remove the mounting screw, and withdraw the old igniter without touching the element.
  5. Install — Mount the new igniter by its bracket only — never touch the element with bare fingers — and reconnect the plug.
  6. Test — Restore power and run a heat cycle, confirming the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace runs the ignition sequence but burners never light
  • Igniter does not glow on a call for heat
  • Visible cracks, breaks, or white spots on the element
  • Furnace locks out after several failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS244HEEA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS244HEEA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS244HEEA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online