ICP Igniter Electrode for RGS244HDEA0AAAA — OEM Direct-Spark Ignitor | Ships Today
ICP

ICP Igniter Electrode for RGS244HDEA0AAAA — OEM Direct-Spark Ignitor | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the OEM ignitor electrode (part number 1179966) for the ICP / Tempstar / Heil RGS244HDEA0AAAA gas furnace. The electrode delivers the high-voltage spark that lights the burner gas on each heating cycle and, on many designs, also serves as the flame-sensing rod that proves flame to the control board. A worn, cracked, or carbon-fouled electrode causes ignition lockouts, delayed or rough lights, and repeated retries before the furnace shuts down on a flame fault. Because the electrode sits directly in the burner flame, the ceramic insulator and metal rod degrade over time and are a routine wear replacement on a no-heat or short-cycling call.

Specifications

Spec Value
Part Number 1179966
Type Direct-Spark Ignitor Electrode
Brand ICP / Tempstar / Heil
Function Spark Ignition / Flame Sensing
Fitment OEM Direct Replacement
Application Gas Furnace

Compatibility

Designed for the ICP-built RGS244HDEA0AAAA gas furnace sold under the ICP, Tempstar, Heil, and Comfortmaker brands. Match the part number on the existing electrode and confirm the bracket and rod geometry before ordering.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment door.
  3. Document — Photograph the electrode position, gap, and ignition cable routing before removal.
  4. Remove — Unplug the high-voltage lead, remove the mounting screws, and lift out the old electrode.
  5. Install — Mount the new electrode, set the spark gap per the furnace spec, and reconnect the lead.
  6. Test — Restore power, call for heat, and confirm a strong spark, clean light, and stable flame proof.

Signs You Need a Replacement

  • Furnace locks out on ignition failure after several retries
  • Delayed, rough, or noisy burner light-off
  • Cracked ceramic insulator or carbon-fouled electrode tip
  • Intermittent flame-sense faults and short-cycling

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS244HDEA0AAAA — OEM Direct-Spark Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS244HDEA0AAAA — OEM Direct-Spark Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS244HDEA0AAAA — OEM Direct-Spark Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.