Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter Electrode for RGS243SSFA0AAAA — Direct OEM Fit | Ships Today
ICP

ICP Igniter Electrode for RGS243SSFA0AAAA — Direct OEM Fit | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM igniter electrode (Part No. 1179966) is responsible for initiating combustion in your ICP RGS243SSFA0AAAA gas furnace. On each heat call the control board energizes the igniter, which produces the high-temperature ignition source needed to light the burner gas. Because the electrode is cycled through extreme heat on every call, it is a normal wear part that eventually cracks, erodes, or fails. A failed igniter is one of the most frequent causes of no-heat conditions: you'll hear the inducer and gas valve cycle, but the burners never light, often ending in a hard lockout after several failed attempts.

Specifications

Spec Value
Part Number 1179966
Type Igniter Electrode
Brand ICP
Application Gas Furnace Ignition
Fit OEM Replacement

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil RGS243SSFA0AAAA gas furnace. Confirm the original part number 1179966 and mounting orientation before installing.

Installation Guide

  1. Safety First — Turn off gas and disconnect power at the breaker; verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position and wire routing before disconnecting.
  4. Remove — Disconnect the igniter lead, remove the mounting screw(s), and lift the old electrode out — handle by the base only.
  5. Install — Mount the new igniter without touching the ceramic/element, then reconnect the lead per your photo.
  6. Test — Restore gas and power and confirm a clean ignition on a heat call.

Signs You Need a Replacement

  • Furnace cycles but burners never light (no-heat)
  • Repeated ignition lockouts after several attempts
  • Visible cracks or erosion on the igniter element
  • Delayed or rough ignition with a whoosh on light-off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS243SSFA0AAAA — Direct OEM Fit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS243SSFA0AAAA — Direct OEM Fit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS243SSFA0AAAA — Direct OEM Fit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online