Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter Electrode for RGS243SREA0AAAA — OEM Part 1179966 | Ships Today
ICP

ICP Igniter Electrode for RGS243SREA0AAAA — OEM Part 1179966 | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM igniter electrode assembly (part number 1179966) for the ICP / Tempstar / Heil RGS243SREA0AAAA gas furnace. The ignition electrode delivers the high-voltage spark that lights the burner on each heat call. As the electrode tip erodes, cracks, or its ceramic insulator carbons over, ignition becomes unreliable — the furnace short cycles, locks out, or fails to light at all, leaving the home without heat. Installing the correct OEM electrode restores consistent, on-demand ignition.

Specifications

Spec Value
Part Number 1179966
Description Ignitor Electrode
Type Ignition Electrode
Brand ICP / Tempstar / Heil
Application Gas Furnace Burner Ignition
Fit OEM Direct Replacement

Compatibility

Built for the ICP / Tempstar / Heil RGS243SREA0AAAA gas furnace and other units originally equipped with electrode 1179966. Confirm the part number and bracket orientation against your existing electrode before ordering.

Installation Guide

  1. Safety First — Shut off gas, disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner service panel.
  3. Document — Photograph the electrode position, gap, and wire routing before disconnecting.
  4. Remove — Disconnect the ignition lead and unfasten the old electrode from the burner assembly.
  5. Install — Mount the new electrode, set the correct gap, and reconnect the lead per your photo.
  6. Test — Restore gas and power, then verify a clean spark and reliable burner light-off.

Signs You Need a Replacement

  • Furnace fails to ignite or locks out on a heat call
  • Weak, intermittent, or no visible spark
  • Short cycling during the ignition sequence
  • Cracked ceramic insulator or eroded electrode tip

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS243SREA0AAAA — OEM Part 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS243SREA0AAAA — OEM Part 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS243SREA0AAAA — OEM Part 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online