Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter Electrode for RGS243SEEA0AAAA — Direct Ignition | Ships Today
ICP

ICP Igniter Electrode for RGS243SEEA0AAAA — Direct Ignition | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM igniter electrode (part #1179966) lights the burners on your ICP/Tempstar/Heil RGS243SEEA0AAAA gas furnace. When the control board calls for heat, the electrode delivers the high-voltage spark that ignites gas at the burner and then provides flame rectification to confirm a stable flame. A cracked ceramic insulator, eroded electrode tip, or carbon buildup will cause the furnace to fail ignition, lock out, or short-cycle. Because the electrode also senses flame, a degraded tip can make the board think the flame went out and shut the gas valve mid-cycle. Replacing this low-cost wear part restores reliable, on-demand ignition and prevents nuisance lockouts during cold weather.

Specifications

Spec Value
Part Number 1179966
Type Igniter Electrode (Direct Ignition)
Brand ICP / Tempstar / Heil
Function Spark Ignition & Flame Sensing
Control Voltage 24V
Fitment OEM Replacement

Compatibility

Direct factory replacement for the ICP/Tempstar/Heil RGS243SEEA0AAAA gas furnace and other models using electrode part #1179966. Verify the mounting bracket and electrode gap match your existing part.

Installation Guide

  1. Safety First — Shut off gas and disconnect furnace power; verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner compartment door.
  3. Document — Photograph the electrode position, gap, and wire routing before removing.
  4. Remove — Disconnect the ignition lead and unscrew the electrode bracket from the burner assembly.
  5. Install — Mount the new electrode, set the gap per your photo, and reconnect the lead.
  6. Test — Restore gas and power, call for heat, and confirm clean spark, ignition, and a stable flame signal.

Signs You Need a Replacement

  • Furnace fails to ignite or locks out after several attempts
  • Cracked or chipped ceramic insulator
  • Weak, erratic, or no spark at the burner
  • Short-cycling caused by lost flame sensing

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS243SEEA0AAAA — Direct Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS243SEEA0AAAA — Direct Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS243SEEA0AAAA — Direct Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR