Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter Electrode for RGS243LEEA0AAAA — OEM Ignition | Ships Today
ICP

ICP Igniter Electrode for RGS243LEEA0AAAA — OEM Ignition | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM Igniter Electrode (part number 1179966) initiates the burner flame on the ICP RGS243LEEA0AAAA gas furnace. On a call for heat the control board energizes the electrode to create the spark that lights the gas at the burner. Igniter electrodes are a common failure point — the tip cracks, erodes, or fouls with oxide, and a furnace that can't establish ignition will lock out and leave the home without heat. Symptoms include audible sparking with no flame, a furnace that ignites then drops out, or repeated ignition-failure lockout codes. The genuine OEM electrode delivers the correct gap, position, and gas-ignition timing for safe, dependable starts.

Specifications

Spec Value
Part Number 1179966
Type Igniter Electrode
Brand ICP / Heil / Tempstar / Comfortmaker
Function Burner ignition
Fitment OEM replacement

Compatibility

Direct OEM replacement igniter electrode for the ICP RGS243LEEA0AAAA gas furnace and related Heil, Tempstar, and Comfortmaker RGS-series furnaces using the same burner ignition assembly. Confirm your existing electrode is marked 1179966 before installing.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, shut off the gas supply, and verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the electrode position, gap, and wire routing before removal.
  4. Remove — Disconnect the ignition lead, unfasten the mounting screw, and withdraw the old electrode without bending the bracket.
  5. Install — Mount the new 1179966 electrode at the correct position/gap and reconnect the lead per your photo.
  6. Test — Restore gas and power, run a heat cycle, and confirm prompt ignition and stable flame with no lockout.

Signs You Need a Replacement

  • Furnace sparks but never lights the burner.
  • Repeated ignition-failure lockouts or fault codes.
  • Cracked ceramic, eroded tip, or heavy oxide buildup on the electrode.
  • Delayed ignition or burner that lights then drops out.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS243LEEA0AAAA — OEM Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS243LEEA0AAAA — OEM Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS243LEEA0AAAA — OEM Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online