Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter Electrode for RGS243LDFA0AAAA — Direct Spark Ignitor | Ships Today
ICP

ICP Igniter Electrode for RGS243LDFA0AAAA — Direct Spark Ignitor | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM igniter electrode (part #1179966) is the ignition component that creates the high-voltage spark needed to light the burners on your ICP/Tempstar/Heil RGS243LDFA0AAAA gas furnace. Mounted at the burner assembly, the electrode delivers the spark that ignites the gas/air mixture on each heating call. When an igniter electrode fails or its tip erodes, the furnace will try to light, fail, and lock out — leaving you with no heat. A cracked ceramic insulator, carbon buildup, or a misaligned gap are the most common causes of ignition failure.

Specifications

Spec Value
Part Number 1179966
Type Igniter Electrode
Brand ICP / Tempstar / Heil
Function Direct Spark Ignition
Mounting Burner Assembly
Fitment OEM Direct Replacement

Compatibility

Designed as a direct-fit replacement for the ICP/Tempstar/Heil RGS243LDFA0AAAA and other furnaces using OEM part 1179966. Always confirm the electrode geometry and mounting bracket match your existing burner assembly before installation.

Installation Guide

  1. Safety First — Shut off the gas supply and disconnect power at the furnace switch, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the electrode wiring and its position relative to the burner before removing it.
  4. Remove — Disconnect the high-voltage lead and unscrew the electrode bracket from the burner assembly.
  5. Install — Mount the new electrode, set the spark gap per spec, and reconnect the ignition lead.
  6. Test — Restore gas and power, call for heat, and confirm a strong spark and clean burner ignition.

Signs You Need a Replacement

  • Furnace clicks but burners won't light
  • System locks out after repeated failed ignition attempts
  • Cracked or carbon-fouled ceramic insulator
  • Weak, erratic, or no visible spark at the electrode tip

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS243LDFA0AAAA — Direct Spark Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS243LDFA0AAAA — Direct Spark Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS243LDFA0AAAA — Direct Spark Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online