Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter Electrode for RGS243HSAA0AAAA — OEM Ignition Electrode | Ships Today
ICP

ICP Igniter Electrode for RGS243HSAA0AAAA — OEM Ignition Electrode | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

OEM igniter electrode (part 1179966) for the ICP / Heil / Tempstar RGS243HSAA0AAAA gas furnace. The igniter electrode is positioned at the burner to ignite the gas/air mixture at the start of each heat call. As the electrode tip erodes, cracks, or develops carbon buildup, ignition becomes weak or intermittent — leading to delayed light-off, rough or noisy ignition, and lockout faults that leave the home without heat. Installing the factory-spec electrode restores a strong, consistent ignition for reliable furnace starts every cycle.

Specifications

Spec Value
Part Number 1179966
Type Igniter / Ignition Electrode
Brand ICP / Heil / Tempstar / Comfortmaker
Application Gas Furnace Burner Ignition
Fit OEM Direct Replacement

Compatibility

Engineered for the ICP-manufactured RGS243HSAA0AAAA and shared across compatible Heil, Tempstar, and Comfortmaker gas furnaces using the same burner ignition assembly. Verify the printed part number on your existing electrode before ordering.

Installation Guide

  1. Safety First — Disconnect power and shut off the gas supply; verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the electrode position, gap, and wiring before removing.
  4. Remove — Disconnect the ignition lead, unfasten the mounting screw, and lift the old electrode out — handle the ceramic by the base only.
  5. Install — Mount the new electrode at the correct gap and reconnect the ignition lead per your photo.
  6. Test — Restore gas and power and confirm prompt, quiet ignition on a heat call.

Signs You Need a Replacement

  • Delayed ignition or a loud whoosh at light-off.
  • Furnace locks out after several failed ignition attempts.
  • No flame on a heat call despite gas and a working valve.
  • Cracked ceramic insulator or eroded/carboned electrode tip.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee on every OEM order.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS243HSAA0AAAA — OEM Ignition Electrode | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS243HSAA0AAAA — OEM Ignition Electrode | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS243HSAA0AAAA — OEM Ignition Electrode | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online