Overview

This is the genuine OEM igniter electrode (part 1179966) for the ICP / Tempstar / Heil RGS243HRFA0AAAA gas furnace. The igniter electrode lights the gas at the burners at the start of each heating cycle. As the element ages it develops micro-cracks and high resistance, leading to no-heat calls, repeated ignition lockouts, or a furnace that clicks but never lights. Because the igniter is brittle, it should never be touched on the element surface and is the first component to check on a furnace that will not fire. Installing the correct OEM igniter restores reliable, on-demand ignition.

Specifications

Spec Value
Part Number 1179966
Type Igniter electrode / ignitor
Brand ICP / Tempstar / Heil
Application Gas furnace burner ignition
Fit OEM Replacement

Compatibility

Designed for the ICP RGS243HRFA0AAAA furnace and shared Tempstar, Heil, Comfortmaker, and Day & Night gas furnace platforms. Verify the bracket shape and connector match your existing igniter before installing.

Installation Guide

  1. Safety First – Disconnect power and shut off the gas; verify zero voltage with a multimeter.
  2. Access – Remove the burner compartment service panel.
  3. Document – Photograph the igniter position, bracket orientation, and wire routing.
  4. Remove – Unplug the connector and remove the mounting screw, then withdraw the old igniter without touching the element.
  5. Install – Seat the new igniter, secure the bracket, and reconnect the harness, handling it only by the ceramic base.
  6. Test – Restore gas and power and confirm the burners light on the first ignition attempt.

Signs You Need a Replacement

  • Furnace clicks or sequences but burners never ignite
  • Repeated ignition lockouts and no-heat cycles
  • Visible cracks, chips, or white-spotting on the element
  • Igniter glows weakly or not at all on a heat call

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS243HRFA0AAAA – OEM Hot Surface Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS243HRFA0AAAA – OEM Hot Surface Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS243HRFA0AAAA – OEM Hot Surface Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.