Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter Electrode for RGS243HEFA0AAAA — Direct Spark | Ships Today
ICP

ICP Igniter Electrode for RGS243HEFA0AAAA — Direct Spark | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM igniter electrode (part 1179966) creates the high-voltage spark that lights the burner on your ICP RGS243HEFA0AAAA furnace. On each call for heat the control board energizes the electrode, the spark ignites the gas, and the flame is then confirmed by the sensing circuit. A cracked ceramic insulator, an eroded or misaligned electrode tip, or a carbon-fouled gap will produce a weak or absent spark — so the furnace clicks but never lights, locks out after several failed trials, or short-cycles on ignition failure. Because the electrode sits directly in the burner flame path, the ceramic and metal degrade over time and the part is a routine wear replacement.

Specifications

Spec Value
Part Number 1179966
Type Igniter / Spark Electrode
Brand ICP / Tempstar / Heil
Application Gas furnace burner ignition
Fit OEM Replacement

Compatibility

Direct OEM fit for the ICP / Tempstar / Heil RGS243HEFA0AAAA. Verify the electrode bracket and spark-gap geometry against your existing part before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect power; verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment / service panel to reach the electrode.
  3. Document — Photograph the electrode position, wire routing, and spark gap before removal.
  4. Remove — Disconnect the ignition lead and unscrew the electrode from its burner bracket.
  5. Install — Mount the new electrode, set the spark gap to spec, and reconnect the ignition lead per your photo.
  6. Test — Restore gas and power, then confirm a strong spark and clean burner ignition on a call for heat.

Signs You Need a Replacement

  • Furnace clicks repeatedly but the burner never lights.
  • Weak, intermittent, or absent spark at the electrode.
  • Cracked ceramic insulator or visibly eroded electrode tip.
  • Control board locks out on repeated ignition failures.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS243HEFA0AAAA — Direct Spark | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS243HEFA0AAAA — Direct Spark | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS243HEFA0AAAA — Direct Spark | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online