Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter Electrode for RGS240SREA0AAAA — OEM Direct Ignition | Ships Today
ICP

ICP Igniter Electrode for RGS240SREA0AAAA — OEM Direct Ignition | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine ICP OEM igniter electrode (part number 1179966) for the RGS240SREA0AAAA gas furnace. The igniter electrode generates the spark that lights the burner gas at the start of every heating cycle. Each ignition sequence subjects the electrode tip to intense heat and combustion byproducts, so over time the tip erodes, cracks, or fouls and the furnace begins to fail on ignition. Installing the exact OEM electrode restores a clean, properly gapped spark and reliable light-off, eliminating no-heat lockouts caused by a worn or damaged igniter.

Specifications

Spec Value
Part Number 1179966
Description Igniter Electrode
Type Direct Ignition Electrode
Brand ICP (Tempstar / Heil / Comfortmaker)
Application Gas Furnace Burner Ignition
Fitment OEM Direct Replacement
Fits Model RGS240SREA0AAAA

Compatibility

Direct OEM replacement for the ICP RGS240SREA0AAAA and equivalent Tempstar, Heil, and Comfortmaker furnaces using this ignition electrode. Match the part number and mounting to your original before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect power, then verify zero voltage with a multimeter before working near the burner assembly.
  2. Access — Remove the furnace service panel to reach the burner/ignition area.
  3. Document — Photograph the electrode position, wiring, and gap before disconnecting.
  4. Remove — Disconnect the ignition lead and unfasten the old electrode from its mounting bracket.
  5. Install — Mount the new electrode, confirm the correct spark gap, and reconnect the ignition lead per your photo.
  6. Test — Restore gas and power, start a heat cycle, and confirm a strong spark and clean burner light-off.

Signs You Need a Replacement

  • Furnace clicks but burners fail to ignite
  • Repeated ignition lockouts or short-cycling on startup
  • Cracked ceramic insulator or eroded/corroded electrode tip
  • Weak, intermittent, or misdirected spark

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS240SREA0AAAA — OEM Direct Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS240SREA0AAAA — OEM Direct Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS240SREA0AAAA — OEM Direct Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online