Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter Electrode for RGS214HTAA0AAAA — Direct Spark Ignition | Ships Today
ICP

ICP Igniter Electrode for RGS214HTAA0AAAA — Direct Spark Ignition | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM igniter electrode (part 1179966) is the ignition component for the ICP / Heil / Tempstar RGS214HTAA0AAAA furnace. The electrode creates the high-voltage spark that lights the burner gas at the start of every heat cycle and, on many platforms, also serves the flame-sensing function that proves the burner has lit. A cracked ceramic insulator, eroded electrode tip, or carbon buildup will cause weak or missing ignition, repeated ignition lockouts, and intermittent no-heat calls. Replacing a worn electrode restores reliable, fast burner light-off and steady flame proving.

Specifications

Spec Value
OEM Part Number 1179966
Type Igniter Electrode Assembly
Brand ICP / Heil / Tempstar
Function Spark ignition / flame sense
Insulator Ceramic
Fitment OEM Direct Replacement

Compatibility

Direct-fit replacement for the ICP / Heil / Tempstar RGS214HTAA0AAAA and related RGS-series furnaces that use this electrode assembly. Confirm the bracket and ceramic geometry match the original before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect power, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the electrode wiring and bracket position before disconnecting.
  4. Remove — Disconnect the high-voltage lead, remove the mounting screw, and withdraw the old electrode.
  5. Install — Mount the new electrode, set the spark gap per spec, and reconnect the ignition lead.
  6. Test — Restore gas and power, start a heat cycle, and confirm a strong spark and stable burner flame.

Signs You Need a Replacement

  • Cracked or chipped ceramic insulator
  • Weak, intermittent, or no spark at the burner
  • Repeated ignition lockouts or no-heat calls
  • Carbon-fouled or eroded electrode tip

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS214HTAA0AAAA — Direct Spark Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS214HTAA0AAAA — Direct Spark Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS214HTAA0AAAA — Direct Spark Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.