Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter Electrode for RGS214HDBEAABTA — OEM 1179966 Direct Spark | Ships Today
ICP

ICP Igniter Electrode for RGS214HDBEAABTA — OEM 1179966 Direct Spark | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM ignitor electrode (OEM 1179966) generates the spark that lights the burners on your ICP Tempstar/Heil RGS214HDBEAABTA furnace. Mounted in the burner assembly, it carries the high-voltage spark from the control board to ignite the gas at the start of each heat cycle, and on many systems it also helps confirm the flame. A cracked ceramic insulator, eroded electrode tip, or carbon buildup leads to weak or no spark — resulting in failed ignition, repeated lockouts, or delayed light-off with a noticeable gas smell at startup.

Specifications

Spec Value
OEM Part Number 1179966
Type Ignitor Electrode (Direct Spark)
Brand ICP / Tempstar / Heil
Function Burner ignition spark electrode
Mounting Burner assembly bracket

Compatibility

Built for the ICP Tempstar Heil RGS214HDBEAABTA furnace and related ICP-family models using this spark electrode. Verify the bracket shape and electrode length against your original part.

Installation Guide

  1. Safety First — Shut off gas and disconnect power; verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner compartment panel.
  3. Document — Photograph the electrode position, gap, and ignition wire routing before removal.
  4. Remove — Disconnect the high-voltage lead and unscrew the electrode from the burner bracket.
  5. Install — Mount the new electrode, set the spark gap to spec, and reconnect the ignition lead per your photo.
  6. Test — Restore gas and power, then run a heat cycle and confirm a strong, immediate spark and clean light-off.

Signs You Need a Replacement

  • No spark or weak intermittent spark on a heat call
  • Cracked or chipped ceramic insulator
  • Repeated ignition lockouts
  • Delayed ignition with gas odor at startup

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS214HDBEAABTA — OEM 1179966 Direct Spark | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS214HDBEAABTA — OEM 1179966 Direct Spark | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS214HDBEAABTA — OEM 1179966 Direct Spark | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online