Overview

This is a genuine OEM igniter electrode (part #1179966) for the ICP/Tempstar/Heil RGS213SFEA0AAAA gas furnace. The igniter electrode is responsible for lighting the burner flame at the start of every heat cycle — without a working igniter, the furnace control board locks out and no heat is produced. The electrode tip degrades over time from repeated thermal cycling, cracking, or oxidation, which is why it is one of the most frequently replaced wear parts in a gas furnace. Common failure symptoms include no ignition on a heat call, a furnace that clicks and tries to light but fails, repeated lockouts, or a visible crack or carbon buildup on the igniter tip.

Specifications

Spec Value
Part Number 1179966
Type Igniter Electrode
Brand ICP / Tempstar / Heil
Function Burner Ignition
Supply 120V Furnace Ignition Circuit
Fit OEM Exact Replacement

Compatibility

Direct OEM replacement for the ICP/Tempstar/Heil RGS213SFEA0AAAA and related ICP-family gas furnaces using the same ignition electrode assembly. Verify the mounting bracket and connector match your existing part before installing.

Installation Guide

  1. Safety First — Shut off the furnace power switch and gas supply, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment door.
  3. Document — Photograph the igniter's wire routing and mounting position.
  4. Remove — Disconnect the igniter wire harness and remove the mounting screw; handle the old igniter only by its ceramic base.
  5. Install — Mount the new igniter without touching the element tip with bare fingers, then reconnect the harness.
  6. Test — Restore power and gas, call for heat, and confirm a clean ignition and steady flame.

Signs You Need a Replacement

  • No ignition or no heat on a thermostat call
  • Furnace attempts to light then locks out
  • Visible crack or carbon buildup on the igniter tip
  • Repeated ignition retries before the burner lights

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS213SFEA0AAAA — Furnace Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS213SFEA0AAAA — Furnace Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS213SFEA0AAAA — Furnace Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.