Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter Electrode for RGS213SFCA0AAAA — Direct Spark | Ships Today
ICP

ICP Igniter Electrode for RGS213SFCA0AAAA — Direct Spark | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM igniter electrode (part number 1179966) is the ignition component for the ICP/Tempstar/Heil RGS213SFCA0AAAA gas furnace. The electrode delivers the high-voltage spark that lights the burner gas on each heat call, and many assemblies double as the flame-sensing electrode that confirms a proper flame. Over time the tip erodes, cracks, or accumulates oxidation, leading to delayed ignition, repeated ignition lockouts, or short-cycling on flame failure. Installing a fresh electrode with the correct gap restores fast, reliable lights and prevents nuisance lockouts during the heating season.

Specifications

Spec Value
Part Number 1179966
Type Direct-Spark Igniter Electrode
Brand ICP / Tempstar / Heil
Function Ignition / Flame Sensing
Fitment OEM

Compatibility

Designed as the factory replacement electrode for the ICP RGS213SFCA0AAAA and related Tempstar, Heil, and Comfortmaker furnaces using the same direct-spark burner ignition system. Confirm the part number and electrode geometry against your existing unit before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect power; verify zero voltage with a multimeter.
  2. Access — Remove the furnace service panel to reach the burner assembly.
  3. Document — Photograph the electrode mounting and ignition wire routing before removing.
  4. Remove — Disconnect the ignition lead and unscrew the electrode bracket from the burner.
  5. Install — Mount the new electrode, set the spark gap per spec, and reconnect the lead.
  6. Test — Restore gas and power, then confirm prompt ignition and stable flame sensing.

Signs You Need a Replacement

  • Delayed or no ignition on a heat call.
  • Repeated ignition lockouts or short-cycling.
  • Cracked porcelain insulator or eroded electrode tip.
  • Visible carbon buildup or corrosion on the tip.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS213SFCA0AAAA — Direct Spark | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS213SFCA0AAAA — Direct Spark | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS213SFCA0AAAA — Direct Spark | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online