Overview

This OEM igniter electrode (Part No. 1179966) provides the ignition source for the ICP RGS213SDCA0AAAA gas furnace. On each heat call the control board energizes the igniter, which heats to the temperature needed to light the burners as the gas valve opens. The igniter is the single most frequently replaced ignition component because the element is fragile and degrades with every heating cycle. A cracked or worn-out igniter is the leading cause of "no heat" complaints — the inducer and gas valve sequence correctly, but the burners never light and the furnace locks out.

Specifications

Spec Value
Part Number 1179966
Type Igniter Electrode
Brand ICP (Tempstar / Heil)
Function Burner Ignition
Fits Model RGS213SDCA0AAAA

Compatibility

Direct-fit replacement for the ICP, Tempstar, Heil, and Comfortmaker RGS213SDCA0AAAA furnace. Use the OEM part number to confirm fitment, as ignition assemblies and mounting brackets vary by furnace platform and generation.

Installation Guide

  1. Safety First — Shut off the gas supply and disconnect power at the furnace switch, then verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment door to expose the igniter near the burner assembly.
  3. Document — Photograph the igniter position, bracket, and wire routing before disconnecting.
  4. Remove — Unplug the igniter lead and remove the mounting screw(s); handle only by the ceramic base, never the element.
  5. Install — Mount the new igniter in the exact original position so it sits in the burner flame path, then reconnect the lead.
  6. Test — Restore gas and power, start a heat call, and confirm the igniter glows and the burners light cleanly.

Signs You Need a Replacement

  • Furnace runs the ignition sequence but burners never light
  • Visible crack, blistering, or break in the igniter element
  • Furnace locks out and shows an ignition-failure fault
  • Intermittent heating that worsens over time

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS213SDCA0AAAA — Direct-Fit OEM | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS213SDCA0AAAA — Direct-Fit OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS213SDCA0AAAA — Direct-Fit OEM | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.