Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter Electrode for RGS213LEAA0AAAA — Direct Spark Ignitor | Ships Today
ICP

ICP Igniter Electrode for RGS213LEAA0AAAA — Direct Spark Ignitor | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM igniter electrode (part 1179966) is the ignition component for the ICP / Heil / Tempstar RGS213LEAA0AAAA gas furnace. The electrode delivers the high-voltage spark that lights the burner on each heating call and, paired with the control board, confirms flame is present. Over time the electrode tip erodes, cracks, or fouls with carbon, causing failed or delayed ignition, repeated lockouts, or short cycling. A clean OEM electrode restores fast, reliable light-off and keeps the furnace out of safety lockout.

Specifications

Spec Value
Part Number 1179966
Type Spark Ignition Electrode
Brand ICP / Heil / Tempstar
Application Gas Furnace Burner Ignition
Fit OEM Direct Replacement

Compatibility

Designed for the ICP/Heil/Tempstar RGS213LEAA0AAAA furnace and matching RGS213 platform models that use the 1179966 ignitor electrode. Match the electrode geometry and mounting bracket to your existing part.

Installation Guide

  1. Safety First — Shut off the gas, disconnect power at the furnace switch and breaker, and verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the electrode position, gap, and wire routing before removal.
  4. Remove — Unscrew the electrode bracket and unplug the ignition lead.
  5. Install — Mount the new electrode at the correct spark gap and reconnect the lead per your photo.
  6. Test — Restore gas and power, then run a heating cycle and confirm a clean, immediate light-off.

Signs You Need a Replacement

  • Furnace clicks but the burner won't light
  • Repeated ignition lockouts or short cycling
  • Cracked ceramic insulator or eroded electrode tip
  • Carbon buildup or visibly weak spark

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS213LEAA0AAAA — Direct Spark Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS213LEAA0AAAA — Direct Spark Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS213LEAA0AAAA — Direct Spark Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online