This is a genuine OEM igniter electrode, part number 1179966, for ICP-built gas furnaces. The ignition electrode delivers the spark (or carries the ignition/sensing path) at the burner that lights the gas at the start of each heating cycle. Over time the electrode tip erodes, cracks, or develops carbon buildup, and the ceramic insulator can crack from repeated thermal cycling. When that happens the furnace fails to light, locks out after several failed ignition attempts, or short-cycles on ignition. Because it is a low-cost, high-wear part, replacing the electrode is a common and inexpensive fix for no-heat calls.

Specifications

Spec Value
Part Number 1179966
Type Igniter / ignition electrode
Brand ICP (Tempstar / Heil / Comfortmaker)
Insulator Ceramic
Application Gas furnace burner ignition

Compatibility

Direct OEM replacement for ICP-family equipment including model RGS213HSCA0AAAA and related Tempstar, Heil, and Comfortmaker gas furnaces. Confirm the part number and electrode geometry against your existing unit before ordering.

Installation Guide

  1. Safety First — Turn off the gas and disconnect power, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment door.
  3. Document — Photograph the electrode position, gap, and wire routing.
  4. Remove — Disconnect the ignition lead, remove the mounting screw(s), and withdraw the old electrode.
  5. Install — Mount the new electrode at the correct gap/position and reattach the ignition lead.
  6. Test — Restore gas and power, then watch a full ignition cycle to confirm a clean light-off.

Signs You Need a Replacement

  • Furnace fails to light or locks out after repeated attempts
  • Cracked ceramic insulator or eroded electrode tip
  • Carbon buildup or visible damage on the electrode
  • Short-cycling or delayed ignition with a whoosh on light-off

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS213HSCA0AAAA — OEM Direct Spark | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS213HSCA0AAAA — OEM Direct Spark | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS213HSCA0AAAA — OEM Direct Spark | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.