This is a genuine OEM igniter electrode, ICP part number 1179966, for the ICP, Tempstar, and Heil RGS213HRCA0AAAA gas furnace. The igniter electrode sits at the burner and creates the high-voltage spark or hot ignition point that lights the gas at the start of each heat cycle. Because it is exposed to direct flame and repeated thermal cycling, the electrode tip and its ceramic insulator degrade over time — cracking, eroding, or developing carbon buildup that prevents reliable ignition. A failing igniter is one of the most common no-heat causes: the inducer and gas valve cycle but the burners never light, and the furnace locks out after several failed ignition attempts.

Specifications

Spec Value
Part Number 1179966
Type Igniter / ignition electrode
Brand ICP / Tempstar / Heil
Application Gas furnace burner ignition
Fit OEM Replacement

Compatibility

Designed for the ICP/Tempstar/Heil RGS213HRCA0AAAA gas furnace. Confirm the electrode mounting bracket and lead routing match your original before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker and shut off the gas, then verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the electrode position, gap, and lead connection before removing it.
  4. Remove — Disconnect the ignition lead and unscrew the electrode bracket. Handle by the bracket only — never touch the ceramic with bare fingers.
  5. Install — Mount the new electrode in the same position with the correct spark gap and reconnect the ignition lead per your photo.
  6. Test — Restore gas and power, run a heat call, and confirm a strong spark and clean burner light-off with no delayed ignition.

Signs You Need a Replacement

  • Furnace cycles the inducer and valve but burners never light.
  • Lockout after repeated failed ignition attempts.
  • Cracked ceramic insulator or eroded/blackened electrode tip.
  • Weak, intermittent, or no visible spark at the burner.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS213HRCA0AAAA — OEM Ignitor 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS213HRCA0AAAA — OEM Ignitor 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS213HRCA0AAAA — OEM Ignitor 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.