Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter Electrode for RGS213HDEA0AAAA — Direct Spark Ignition | Ships Today
ICP

ICP Igniter Electrode for RGS213HDEA0AAAA — Direct Spark Ignition | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM igniter electrode (part 1179966) creates the high-voltage spark that lights the burner gas on ignition-equipped ICP / Heil / Tempstar furnaces. The electrode's ceramic insulator holds a precise spark gap; when the control board sends high voltage, an arc jumps the gap and ignites the gas as it reaches the burner. The same electrode tip often doubles as the flame-sensing path that confirms a successful light. Cracked ceramic, an eroded or carbon-fouled tip, or a drifted gap leads to no ignition, repeated ignition retries, or nuisance lockouts on a cold start. Because the electrode sits in direct flame, it is a normal wear item — replacing it restores fast, reliable lighting and dependable flame proving.

Specifications

Spec Value
Part Number 1179966
Type Igniter Electrode (Spark)
Brand ICP / Heil / Tempstar
Function Direct spark ignition / flame sensing
Fitment OEM

Compatibility

Designed for the ICP / Heil / Tempstar / Comfortmaker RGS213HDEA0AAAA gas furnace and related RGS-series burner assemblies that use this electrode. Confirm the electrode bracket and gas-train layout match before installing.

Installation Guide

  1. Safety First — Disconnect electrical power and shut off the gas supply, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment door to expose the burner assembly.
  3. Document — Photograph the electrode position, bracket, and ignition lead routing before removal.
  4. Remove — Disconnect the high-voltage lead, unfasten the electrode bracket screw, and lift out the old electrode without touching the ceramic.
  5. Install — Mount the new electrode, verify the spark gap matches spec, and reconnect the ignition lead per your photo.
  6. Test — Restore gas and power and confirm a strong spark and clean burner light on a heat call.

Signs You Need a Replacement

  • Furnace clicks/sparks but the burner won't light.
  • Repeated ignition retries or hard lockout on cold starts.
  • Cracked or chipped ceramic insulator.
  • Carbon-fouled, eroded, or bent electrode tip.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS213HDEA0AAAA — Direct Spark Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS213HDEA0AAAA — Direct Spark Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS213HDEA0AAAA — Direct Spark Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera