Overview

This is a genuine OEM igniter electrode, part number 1179966, for the ICP Tempstar Heil RGS210STEA0AAAA gas furnace. The igniter electrode delivers the spark or ignition source that lights the burner on a call for heat and, in many designs, also helps confirm flame. A cracked ceramic insulator, an eroded electrode tip, or carbon buildup prevents reliable ignition, causing the furnace to lock out, repeatedly retry ignition, or fail to fire at all. Installing a fresh electrode restores fast, dependable burner light-off.

Specifications

Spec Value
Part Number 1179966
Type Igniter Electrode
Brand ICP / Tempstar / Heil
Application Gas Furnace Burner Ignition

Compatibility

Direct-fit replacement for the ICP Tempstar Heil RGS210STEA0AAAA and related RGS-series gas furnaces using this igniter electrode. Match the part number and mounting style to your existing electrode before ordering.

Installation Guide

  1. Safety First — Disconnect power at the service switch and breaker and shut off the gas supply; verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner compartment door.
  3. Document — Photograph the electrode position, gap, and wiring before removal.
  4. Remove — Disconnect the ignition lead and unscrew the old electrode from the burner assembly; handle the ceramic carefully.
  5. Install — Mount the new electrode, set the proper gap, and reconnect the ignition lead per your photo.
  6. Test — Restore gas and power, then watch a full ignition cycle to confirm a strong spark and steady flame.

Signs You Need a Replacement

  • Furnace fails to light or locks out on ignition
  • Repeated ignition retries before firing
  • Cracked or chipped ceramic insulator
  • Eroded, corroded, or carbon-fouled electrode tip

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS210STEA0AAAA — Direct Ignition Electrode | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS210STEA0AAAA — Direct Ignition Electrode | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS210STEA0AAAA — Direct Ignition Electrode | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.