Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter Electrode for RGS210SRCA0AAAA — OEM Ignition | Ships Today
ICP

ICP Igniter Electrode for RGS210SRCA0AAAA — OEM Ignition | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM igniter electrode (part #1179966) for the ICP/Heil/Tempstar RGS210SRCA0AAAA gas furnace. The igniter electrode produces the ignition source that lights the burners at the start of each heating cycle. A cracked, fouled, or worn electrode is a leading cause of intermittent or failed ignition — the furnace will call for heat, run its inducer and gas valve sequence, but fail to light, often locking out after several tries. Replacing a fatigued electrode restores reliable, fast ignition and prevents repeated lockouts on cold mornings.

Specifications

Spec Value
Part Number 1179966
Type Igniter electrode
Brand ICP / Heil / Tempstar
Application Gas furnace ignition

Compatibility

Direct-fit replacement for the ICP/Heil/Tempstar RGS210SRCA0AAAA and related RGS210 family gas furnaces that specify part #1179966. Confirm the part number on your existing igniter before ordering.

Installation Guide

  1. Safety First — Turn off gas and disconnect electrical power; verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner compartment door.
  3. Document — Photograph the igniter position, gap, and wiring before removal.
  4. Remove — Disconnect the igniter lead and unscrew the electrode bracket; handle the new electrode by its base only, never the tip.
  5. Install — Mount the new electrode at the correct gap and orientation, then reconnect the lead per your photo.
  6. Test — Restore gas and power, start a heat cycle, and confirm clean, prompt ignition.

Signs You Need a Replacement

  • Furnace tries to light but fails and locks out.
  • Delayed ignition or a small rollout/puff at startup.
  • Visible cracks, corrosion, or carbon buildup on the electrode.
  • Intermittent no-heat calls that clear after a reset.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS210SRCA0AAAA — OEM Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS210SRCA0AAAA — OEM Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS210SRCA0AAAA — OEM Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online