Overview

This is a genuine OEM igniter electrode, OEM part number 1179966, for the ICP / Tempstar / Heil RGS210SFAA0AAAA gas furnace. The electrode produces the high-voltage spark that lights the burner gas at the start of every heating cycle and, in many configurations, also senses the resulting flame to confirm ignition. The ceramic insulator carries the spark tip at a precise gap to the burner; over time the tip erodes, the ceramic cracks, or carbon and oxide buildup fouls the electrode so it can no longer reliably light the gas. A failing electrode is a leading cause of intermittent no-heat lockouts — the furnace tries several times to ignite, fails to prove flame, and shuts down on a safety lockout.

Specifications

Spec Value
OEM Part Number 1179966
Type Spark Ignition Electrode
Function Ignition / Flame Sensing Electrode
Insulator Ceramic
Brand ICP / Tempstar / Heil

Compatibility

Fits the ICP RGS210SFAA0AAAA and shares the platform with ICP-built Tempstar, Heil, and Comfortmaker furnaces specifying electrode 1179966. Confirm the printed OEM number and electrode geometry against your existing part before ordering.

Installation Guide

  1. Safety First — Shut off the gas, disconnect power at the furnace switch and breaker, and verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the electrode mounting, wire routing, and spark gap before removal.
  4. Remove — Disconnect the high-voltage lead and unscrew the electrode bracket from the burner assembly.
  5. Install — Mount the new electrode, set it per the spec gap, and reconnect the ignition lead.
  6. Test — Restore gas and power, run a heat cycle, and confirm a strong spark and clean, immediate burner ignition.

Signs You Need a Replacement

  • Furnace clicks and tries to light repeatedly, then locks out on no-flame.
  • Cracked ceramic insulator or visibly eroded or burned electrode tip.
  • Delayed ignition with a noticeable "whoomp" when the burner finally lights.
  • Weak, intermittent, or no spark at the burner.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS210SFAA0AAAA — 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS210SFAA0AAAA — 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS210SFAA0AAAA — 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.