Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter Electrode for RGS210LTCA0AAAA — Direct Spark | Ships Today
ICP

ICP Igniter Electrode for RGS210LTCA0AAAA — Direct Spark | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM igniter electrode (part 1179966) is the ignition component that lights the burner on the ICP / Tempstar / Heil RGS210LTCA0AAAA. The electrode delivers the high-voltage spark that ignites the gas at the burner on a call for heat, and it also helps establish a stable flame for the control sequence. A cracked ceramic insulator, eroded electrode tip, or carbon buildup causes weak or missing spark — resulting in a furnace that clicks but won't light, short-cycles on ignition lockout, or fails to maintain heat. Replacing a worn electrode restores fast, reliable ignition every cycle.

Specifications

Spec Value
OEM Part Number 1179966
Type Igniter Electrode (Direct Spark)
Brand ICP / Tempstar / Heil
Function Burner Ignition
Application Gas Furnace

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil RGS210LTCA0AAAA gas furnace. This electrode is used across comparable ICP-family furnaces with direct-spark ignition — confirm the part number and physical mounting against your existing electrode before ordering.

Installation Guide

  1. Safety First — Shut off gas at the valve, disconnect power at the breaker, and verify zero voltage with a multimeter. Let the furnace cool fully.
  2. Access — Remove the furnace burner/service panel to reach the burner assembly.
  3. Document — Photograph the electrode position, gap, and wire routing before removing.
  4. Remove — Disconnect the ignition lead, remove the mounting screw, and lift out the old electrode. Avoid touching the ceramic with bare oily hands.
  5. Install — Mount the new electrode, set it to the original position and gap, and reconnect the ignition lead.
  6. Test — Restore gas and power, call for heat, and confirm a strong, consistent spark and clean burner light.

Signs You Need a Replacement

  • Furnace clicks repeatedly but the burner won't light.
  • System locks out on ignition failure after several attempts.
  • Weak, intermittent, or yellow spark at the electrode.
  • Cracked ceramic insulator or heavy carbon/erosion on the tip.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS210LTCA0AAAA — Direct Spark | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS210LTCA0AAAA — Direct Spark | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS210LTCA0AAAA — Direct Spark | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online