Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter Electrode for RGS210HRCA0AAAA — OEM Ignition | Ships Today
ICP

ICP Igniter Electrode for RGS210HRCA0AAAA — OEM Ignition | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM igniter electrode, part number 1179966, ignites the burner gas on the ICP Tempstar Heil RGS210HRCA0AAAA furnace. On each heat call the control board energizes the igniter, which heats or sparks to light the main burners, then verifies flame through the sensing circuit. The igniter is a wear part: repeated thermal cycling makes the element brittle, cracked, or open over time. A failed igniter is the single most common reason a furnace runs the inducer and clicks but never lights, or short-cycles on ignition lockout. Replacing it with the correct OEM electrode restores fast, reliable, on-spec ignition and avoids the no-heat callbacks caused by aftermarket parts with the wrong resistance or geometry.

Specifications

Spec Value
Part Number 1179966
Type Igniter Electrode
Function Burner Ignition
Brand ICP / Tempstar / Heil
Application Gas Furnace
Fitment OEM

Compatibility

Designed for ICP-family gas furnaces (Tempstar, Heil, Comfortmaker), including model RGS210HRCA0AAAA and related RGS210 series units. Confirm the mounting bracket and lead connector match your original igniter before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect electrical power; verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position and wiring before removal.
  4. Remove — Unplug the igniter lead and remove the mounting screw(s); handle only by the ceramic base, never the element.
  5. Install — Mount the new igniter without touching the fragile element, then reconnect the lead.
  6. Test — Restore gas and power, run a heat cycle, and confirm the burners light promptly and hold flame.

Signs You Need a Replacement

  • Furnace clicks and runs the inducer but never lights.
  • Repeated ignition lockouts or short-cycling on startup.
  • Visible cracks or a broken element on the old igniter.
  • No glow or no spark during the ignition sequence.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS210HRCA0AAAA — OEM Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS210HRCA0AAAA — OEM Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS210HRCA0AAAA — OEM Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.