Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter Electrode for RGS210HRAA0AAAA — Direct Ignition | Ships Today
ICP

ICP Igniter Electrode for RGS210HRAA0AAAA — Direct Ignition | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM igniter electrode (part 1179966) for ICP, Tempstar, and Heil gas furnaces. The electrode delivers the high-voltage spark or ignition point that lights the burner gas at the start of each heat cycle. Positioned at the burner, it must maintain the correct gap and a clean, uncracked ceramic insulator to fire reliably. Over time the electrode tip erodes, the porcelain insulator can crack from repeated thermal cycling, and carbon buildup can foul the gap — any of which leads to delayed ignition, repeated ignition lockouts, or a furnace that will not light at all. Replacing a worn igniter electrode restores fast, consistent burner ignition and eliminates the frustrating short-cycling and no-heat calls that a degraded electrode causes.

Specifications

Spec Value
Part Number 1179966
Type Igniter Electrode (Direct Ignition)
Brand ICP / Tempstar / Heil
Application Gas Furnace Burner Ignition
Insulator Ceramic / Porcelain

Compatibility

Designed for the ICP/Tempstar/Heil RGS210HRAA0AAAA gas furnace and other ICP-family models that use the 1179966 igniter electrode. Confirm the part number against your existing electrode before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the electrode position, gap, and wiring before removal.
  4. Remove — Disconnect the ignition lead and unscrew the electrode from the burner assembly.
  5. Install — Mount the new electrode, set it to the manufacturer's gap, and reconnect the ignition lead.
  6. Test — Restore gas and power, then run a heat call and confirm prompt, reliable burner ignition.

Signs You Need a Replacement

  • Repeated ignition lockouts or no-light condition
  • Delayed ignition with a small "poof" at startup
  • Cracked porcelain insulator or eroded electrode tip
  • Carbon fouling across the spark gap

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS210HRAA0AAAA — Direct Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS210HRAA0AAAA — Direct Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS210HRAA0AAAA — Direct Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online