Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Igniter Electrode for RGS210HFAA0AAAA — Direct Spark | Ships Today
ICP

ICP Igniter Electrode for RGS210HFAA0AAAA — Direct Spark | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM ignitor electrode (part 1179966) for ICP / Tempstar / Heil model RGS210HFAA0AAAA produces the high-voltage spark that lights the burners on a direct-spark gas furnace. The electrode sits at the burner and arcs to ground (or to a paired rod) to ignite the gas at the start of each heating cycle. A cracked ceramic insulator, eroded electrode tip, or incorrect spark gap leads to ignition failure, delayed ignition with a startup "whump," or repeated lockouts as the control gives up after failed ignition attempts.

Specifications

Spec Value
Part Number 1179966
Type Direct Spark Ignitor Electrode
Brand ICP / Tempstar / Heil
Application Gas Furnace Burner Ignition
Fitment OEM Replacement

Compatibility

Designed for ICP-family RGS-series gas furnaces, including model RGS210HFAA0AAAA, and shared across Tempstar, Heil, and Comfortmaker furnaces using this direct-spark electrode. Confirm the bracket shape and spark gap against your existing part before installing.

Installation Guide

  1. Safety First — Disconnect power and shut off the gas supply, then verify zero voltage with a multimeter before working near the burners.
  2. Access — Remove the furnace service panel to expose the burner assembly.
  3. Document — Photograph the electrode position, spark gap, and igniter lead routing before removal.
  4. Remove — Disconnect the high-voltage lead and unscrew the electrode bracket from the burner.
  5. Install — Mount the new electrode at the correct gap, reconnect the lead, and keep ceramic clean of fingerprints/oil.
  6. Test — Restore gas and power, then watch a full ignition cycle for a strong, immediate spark and clean light-off.

Signs You Need a Replacement

  • Furnace fails to ignite or locks out after several attempts
  • Delayed ignition with a loud "whump" at startup
  • Cracked or chipped ceramic insulator
  • Weak, erratic, or no visible spark at the electrode

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS210HFAA0AAAA — Direct Spark | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS210HFAA0AAAA — Direct Spark | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS210HFAA0AAAA — Direct Spark | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online