ICP Igniter Electrode for RGS210HEEA0AAAA — OEM 1179966 | Ships Today
ICP

ICP Igniter Electrode for RGS210HEEA0AAAA — OEM 1179966 | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM igniter electrode, part number 1179966, provides the spark that lights the burners in ICP, Heil, and Tempstar gas furnaces. The electrode sits at the burner and generates the high-voltage arc that ignites gas at the start of each heat cycle. Over time the electrode tip erodes, cracks, or fouls with carbon, leading to delayed ignition, repeated ignition retries, hard lockouts, or no heat at all. Replacing a worn electrode restores fast, dependable light-off and prevents the unsafe gas accumulation that comes from failed ignition attempts.

Specifications

Spec Value
Part Number 1179966
Type Igniter electrode
Function Burner spark ignition
Brand ICP / Heil / Tempstar
Application Gas furnace
Fitment OEM

Compatibility

Designed for the ICP/Tempstar/Heil RGS210HEEA0AAAA gas furnace and other ICP-family models using electrode 1179966. Confirm the part number and electrode mounting orientation against your existing unit before ordering.

Installation Guide

  1. Safety First — Turn off the gas supply, disconnect power, and verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the electrode position, gap, and wire routing before removal.
  4. Remove — Disconnect the ignition lead and unscrew the old electrode from the burner bracket.
  5. Install — Mount the new electrode, set the correct spark gap per the unit spec, and reconnect the ignition lead.
  6. Test — Restore gas and power, start a heat call, and confirm a strong spark and prompt burner ignition.

Signs You Need a Replacement

  • Furnace clicks/tries to ignite but won't light.
  • Delayed ignition with a noticeable gas smell at light-off.
  • Repeated ignition retries ending in lockout / no heat.
  • Cracked ceramic, eroded tip, or heavy carbon on the electrode.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS210HEEA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS210HEEA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS210HEEA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.